Selection Of Installation Equipment - Scandomestic IKF 160-1 User Manual

Table of Contents

Advertisement

Available languages

Available languages

Product Size L×W×H(mm)
Building-in Dimensions A×B (mm)
Weight and Dimensions are approximate. Because we continually strive to
improve our products we may change specifications and designs without prior
notice.
Installation

Selection of installation equipment

Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select
heat-resistant work surface material to avoid larger deformation caused by the
heat radiation from the hotplate. As shown below:
H
D
X
B
X
L(mm)
W(mm)
590
520
Under any circumstances, make sure the Induction cooker hob is well ventilated
and the air inlet and outlet are not blocked. Ensure the Induction cooker hob is in
good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least 760mm.
L
W
X
H(mm)
D(mm)
60
56
590X520X60
560X490
X
A
A(mm)
B(mm)
+4
560
490
+1
16
X(mm)
+4
50 mini
+1

Advertisement

Table of Contents
loading

Table of Contents