The Info Menu Item; Info; Measured Values Lt Status Grid Status; Device Information - Fronius Primo Series Operating Instructions Manual

Inverter for grid-connected photovoltaic systems
Table of Contents

Advertisement

The INFO menu item

INFO

Measured values
Measured values Display range:
LT status
Grid status
LT status
Grid status
Device Informa-
Used to display settings relevant to a power supply company. The displayed values de-
tion
pend on the respective country setup or device-specific inverter settings.
PV Iso. / Ext. Lim. / U PV1 / U PV2 / GVD-
PR / Fan #1
PV Iso.
Insulation resistance of the PV system
(for ungrounded solar modules and for solar modules grounded at the
negative pole)
Ext. Lim.
External power reduction in percent e.g. specified by grid operator
U PV1
Current DC voltage at the terminal, also if the inverter is not feeding
in at all (from the first MPP Tracker)
U PV 2
Current DC voltage at the terminal, also if the inverter is not feeding
in at all (from the second MPP Tracker)
GVDPR
Grid voltage-dependent power reduction
Fan #1
Percentage value of the fan's target power
The status display of the last error that occurred in the inverter can be
shown.
IMPORTANT! Status codes 306 (Power low) and 307 (DC low) ap-
pear naturally every morning and evening due to low solar irradiance.
These status codes are not the result of a fault.
-
After pressing the "Enter" key, the power stage set status and the
last error that occurred are displayed
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the status and error list
The last 5 grid errors that occurred can be displayed:
-
After pressing the "Enter" key, the last 5 grid errors that occurred
are displayed
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the grid error display
INFO
(information on device and software)
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents