Problem
Unable to pair PED
to Flight Stream
210/510.
Flight Stream 210 is
connected but
Connext Setup
page is grayed out.
PED is not
receiving any data
from Flight Stream
210/510.
PED is not
receiving data from
the GDL 88
(e.g., ADS-B traffic
and FIS-B).
190-01007-C1
Rev. 1

Table 5-13 Flight Stream Troubleshooting

Possible Cause
Trying to pair with the device
while not on the Bluetooth
Pairing page.
Flight Stream paired device
storage is full.
Ensure that the Flight Stream
has the latest certified
software version.
Flight Stream 210 has lost
communication with the
GTN Xi.
Devices need to be re-synced
with each other.
Flight Stream 210 has lost
communication with the GDL
88.
Corrective Action
Access the Connext Bluetooth Pairing page
by pressing Home > System > Connext Setup
> Flight Stream 210. If Flight Stream 210 is the
only Bluetooth device, touching Connext Setup
will automatically open the Flight Stream 210
page.
Refer to the list of paired devices and verify that
the queue is not full. If 13 devices have been
previously paired with the Flight Stream,
remove a device from the list to pair the new
device with the Flight Stream.
Check software version and update if there is a
newer approved version.
Check that the Flight Stream 210 connector is
fully seated.
Check RS-232 wires and connections between
the GTN Xi and Flight Stream 210.
Check power and ground wires and
connections to the Flight Stream 210.
1. Access the Connext Bluetooth Pairing
page by pressing Home > System >
Connext Setup.
2. Remove the PED from the list of paired
devices on the GTN Xi.
3. Remove the list of Bluetooth devices on the
PED.
4. Re-pair the devices.
Check that PED is paired to Flight Stream 210.
Refer to the steps above for details.
Check that the Flight Stream 210 connector is
fully seated.
Check RS-422 wires and connections between
the GDL 88 and Flight Stream 210.
Check power and ground wires and
connections to the Flight Stream 210.
Check that the GDL 88 RS-422 port is
configured for Connext Format 1.
GTN Xi Part 23 AML STC Maintenance Manual