Hot melt unit
Table of Contents

Advertisement

Vacuum Feeder Assembly Instructions
Installation - Continued
Valco Melton
35. Attach the 10 mm tubing to the push-in 90° swivel fitting on the air
valve.
36. Slide the level probe through the cable clamp on the top of the lid.
Use a Phillips-head screwdriver to tighten the probe to the clamp.
The top of the sensor should be about .25" above the top of the
clamp.
37. Connect the three (3) pin, white JST connector from the amplifier
box to the temperature control board.
38. Install the red jumper cable to the door switch location on the
temperature control board.
39. Connect the flying leads, with the white ferrules, to the feeder
location on the temperature control board.
40. Attach the flying terminal ring from the cable assembly to one of
the grounding studs on the base of the chassis.
IS0231
7

Hide quick links: