Troubleshooting
Problem
Error code
appears on display
and cooker beeps
continuously
Any other servicing should be performed by an authorized service representative.
Error Code
C1
C2
C6
Faulty sensor.
C6H
C6L
Temperature is too high
because inner pot is not
placed in the cooker base.
C5
Temperature is too high
because there is no water
in inner pot.
Not enough liquid.
C7
or
NoPr
Quick release button
is in the Vent position.
Sensor connectors on Air
C9
Fryer Lid and cooker base
are not making full contact.
Lid is not in the correct
Lid
position for the selected
programme.
High temperature detected
at bottom of inner pot;
Burn /
cooker automatically reduces
Food burn
temperature to avoid
overheating.
Pressure has accumulated
PrSE
during a non-pressure
cooking programme.
Meaning of error code
Contact
Press Cancel and wait for
heating element to cool;
ensure there are no foreign
objects in cooker base; insert
or reposition inner pot in
cooker base and re-enter
commands.
Add 500 mL of a thin cooking
liquid to the inner pot
Begin by adding 2 cups (16
oz / 500 mL) of a thin cooking
liquid to inner pot. Add more
liquid as required.
Flick quick release button
to ensure it is in the Seal
position.
Press the lid down slightly to
ensure that .the female lid
sensor connector contacts the
male base sensor connector.
Open and close the lid.
Do not use a lid when using
Sauté.
Starch deposits at the bottom
of the inner pot may have
blocked heat dissipation.
Turn the cooker off, release
pressure according to the
recipe, and inspect the
bottom of the inner pot.
Press quick release button
down until it clicks into Vent
position.
Customer
Care.
61