Problem
The unit is not
cold enough
(continued)
The unit is not cold The door was left open
enough (Frost free
units only)
The unit frosts
up
Water is leaking
out the back
of the unit
Ice cubes
sticking together
Noise during
operation
No ice
Not enough ice
Water leaks into
ice bucket
Fresh food section
on Combo units
too cold
Possible Cause
causing the evaporator
behind the back wall to
fill with frost preventing
proper air flow and cooling.
Unit is manual
defrost model
Door gasket not
sealing properly
High ambient
temperatures or
humidity
Water supply
connection leaking
Door gasket not
sealing properly
Infrequent use of cubes
Copper water supply
tubing contacting
internal components
Fan blade touching
obstruction (wiring,
foam insulation, etc.)
Bin arm locked in
upright position
Control set too cold
Ice cube size too
large
Water level set too
high
Ice bucket not fully
inserted
Temperature control
set too cold
28
Remedy
For model 29AD only:
is the defrost timer set
to the correct time of day?
See INITIAL START-UP
Turn off the unit to manually
defrost the evaporator.
See DEFROSTING.
Models BI-15, 95, 98,
and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING
Adjust door. See
ALIGNING THE DOOR
Defrost unit manually.
See DEFROSTING
Tighten fitting. See
CONNECTING THE
WATER SUPPLY
Adjust door. See
ALIGNING THE DOOR
Break apart cubes
Carefully bend tubing
away from cabinet and
components
Remove obstruction
Lower bin arm
Adjust control to a
warmer setting
(COUNTER-CLOCKWISE)
Set cube size smaller.
See ADJUSTING ICE
CUBE SIZE
Set cube size smaller.
See ADJUSTING ICE
CUBE SIZE
Push ice bucket
into place
Set control to warmer
setting (COUNTER-
CLOCKWISE)