Fill your cleaning tank with the cleaning / sanitizing agent according to the mixing ratios given by the
manufacturer of the agent. (e.g. when using P3 from ECOLAB -> 50ml for 1 litre water = 5%
solution) In order to achieve a proper mixing in the cleaning tank, it is recommended to first fill in the
agent and then top-of with clean water.
Connect the syrup lines to the cleaning tank and dispense cleaning / sanitization agent from every
single dispense valve. Make sure that agent leaves from all installed taps.
7.2.2

Flushing-in of sanitization agent into water side (e.g. P3 Ansep CIP from Ecolab)

Close the water- + the CO
Disconnect the water supply to the unit and cut the power supply to the carbonator pump in order to
avoid dry running of the pump (e.g. by pulling the plug of the pump).
Connect the water line feeding the dispenser to CO
of the system. This ensures that the sanitizing agent that is afterwards flushed into the dispenser is
not being diluted e.g. in the carbonator bowl. Afterwards close the gas supply again and
depressurize the system.
Connect the cleaning tank to the water inlet of the dispenser and pressurize the tank with approx. 3
bars pressure (Attention! Remove any water filters before doing this!)
Pull the safety relieve valve on the carbonator bowl and carefully let some sanitizing agent leave the
valve. This ensures, that the carbonator bowl is flooded completely with sanitizing agent all the way
to the top.
Attention! Avoid that excessive amounts (= >50ml) of agent is being introduced into the
water bath, as this will carry the risk of corrosion of metal parts in the water bath. In case
larger amounts were spilled, the water in the water bath needs to be replaced.
Flood the complete dispense system with the cleaning / sanitizing agent by operating the post-mix
valves. Ensure, that on all valves clearly visible agent is being drawn.
Effect- / working time for the cleaning / sanitizing agent is min. 20 minutes!
In the meantime remove the dispense nozzles from the valves and sanitize them manually by putting
them for 20 minutes into sanitizing agent. In case it is seen that the nozzles are heavily dirty, clean
the nozzles mechanically by using a clean brush and sanitization agent.
7.2.3

Flushing-out of sanitization agent out of syrup side (e.g. P3 Ansep CIP from Ecolab)

Disconnect the cleaning tank and bring out any remaining sanitizing agent from the syrup lines by
using CO
gas. Afterwards close the CO
2
valves.
Connect the water distributor and sufficiently flush clean water through the syrup lines (for this
please open only the syrup side of the dispense valves). In case a hygiene water filter is being used
with the dispenser, it is recommended to use for this flushing the water coming from the hygiene
filter.
Attention! It must be ensured, that no cleaning / sanitizing agent remains in the dispense system
after service (risk of health injuries)! The prove that all agent residues have been removed must be
tested with indicator or test papers (contact agent manufacturer) & must be documented
Connect the syrup containers again to the syrup lines and dispense syrup on the post-mix valves
until a consistent flow of syrup occurs again.
Cornelius Deutschland GmbH
Document no: TD1005601EN
Version A, 24.09.2019, Index 0
supply to the unit and depressurize the system with the taps
2
supply and depressurize the system via the dispense
2
Energize R134a 60Hz
gas pressure and drain all water from the tubing
2
Manual operation undercounter cooler
Energize R134a 60Hz
Page 17