4 - Trunk Output Timing: Controls the output timing/type of the RED/WHITE Trunk
output.
1 Sec. - 1 second pulse output.
10 Sec. - Continuous output for 10 seconds.
20 Sec. - Continuous output for 20 seconds.
Latched until IGN ON - Continuous output until the vehicle's ignition is turned
ON.
Latched ON until Button Press - Continuous output until the activation button
is pressed again.
5 - Horn Output Timing: Control the minimum horn pulse time in milliseconds, some
vehicles will require a longer pulse to activate the factory horn.
16mS
6 - Real Panic: Controls the panic out when triggered from the transmitter.
ON - Randomized horn honks when panic is triggered.
OFF - Standard pattern horn honks when panic is triggered.
7 - AUX 1: Controls the VIOLET/BLACK AUX 1 output activation type and timing.
1 Sec. Pulse - Single 1 second pulse.
Latched - Output stays active until button is pressed again.
Latched until IGN ON - Output stays active until the ignition is turned on.
Dome Light Output - Output is used for illuminated entry and is not controlled
by the AUX 1 function of the transmitter.
8 - AUX 2: Controls the WHITE/BLACK AUX 2 output activation type and timing.
1 Sec. - Single 1 second pulse.
Latched - Output stays active until button is pressed again.
Latched until IGN ON - Output stays active until the ignition is turned on.
10 Sec. w/ Arm - Output stays active for 10 seconds with press of lock button.
10 Sec. w/ Disarm - Output stays active for 10 seconds with press of unlock
button.
L.E.D. Output - Output will mimic the flash patterns of the systems status LED.
2017 Voxx Electronics Corporation. All rights reserved.
10mS
30mS
40mS
50mS
27
Need help?
Do you have a question about the caSEC and is the answer not in the manual?