Transmission / Receiving Protocol - LG LU34 Z Series Installation Manual

Table of Contents

Advertisement

TRANSMISSION / RECEIVING PROTOCOL

* (Depending on Model)
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
[Command 1] : First command to control the TV. (j, k, m or x)
[Command 2] : Second command to control the TV.
[Set ID] : You can adjust the set ID to choose desired monitor ID number in option menu.
Adjustment range is 1 to 99. When selecting Set ID '0' , every connected set is controlled. Set ID
is indicated as decimal (1 to 99) on menu and as Hexa decimal (0 x 0 to 0 x 63) on transmission/
receiving protocol.
[Data] : To transmit command data (hexadecimal). Transmit 'FF' data to read status of command.
[Cr] : Carriage Return - ASCII code '0 x 0D'
[ ] : Space – ASCII code '0 x 20'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on this format when receiving normal data. At
this time, if the data is data read mode, it indicates present status data. If the data is data write
mode, it returns the data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on this format when receiving abnormal data
from non-viable functions or communication errors.
Data 00: Illegal Code
Real data mapping (Hexadecimal : Decimal)
* When you enter the [Data] in hexadecimal, refer to following conversion table.
* Programme Tune (ma) Command uses two-byte hexadecimal value([Data]) to select Programme
number.
00 : Step 0
01 : Step 1 (Set ID 1)
...
0A : Step 10 (Set ID 10)
...
0F : Step 15 (Set ID 15)
10 : Step 16 (Set ID 16)
...
46
32 : Step 50 (Set ID 50)
33 : Step 51 (Set ID 51)
...
63 : Step 99 (Set ID 99)
...
C7 : Step 199
C8 : Step 200
...
FE : Step 254
FF : Step 255
...
01 00 : Step 256
...
27 0E : Step 9998
27 0F : Step 9999
...