Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
40-584/585A/586A/587A User Manual PXI 2 Amp 1-Pole Very High Density Matrix Modules pickeringtest.com Issue 6.2 February 2020...
Page 4
Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
Pour indiquer que des appareils sensibles present and handling precautions should be statiques sont présents et les précautions de followed. manipulation doivent être suivies. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A REED RELAY MODULE 40-110/115/120/125 Page (IV) Page (IV)
Blanking panels are signaux d’E/S utilisateur qui peuvent être présents. available to order from Pickering in a variety of slot Les obturateurs sont disponibles sur commande chez widths. If the product is not used in this manner for Pickering dans une variété...
Page 9
“arrêt an emergency press the red “emergency stop” d’urgence” situé sur l’avant de l’unité. button situated on the front of the unit. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page (VIII) GENERAL PURPOSE 2A RELAY MODULE 40-131/132 Page (VIII)
• Supported by BIRST ™ and eBIRST ™ Test Tools • 3 Year Warranty The 40-584, 40-585A, 40-586A and 40-587A are 256 crosspoint PXI matrices with single pole switching. The matrix configurations are 128x2, 64x4, 32x8 or 16x16 using electro-mechanical relays with 2A current handling.
Page 11
All modules are fully CE compliant and meet applicable EU 4MHz (40-584-001) Bandwidth: directives: Low-voltage safety EN61010-1:2010, EMC Immunity 15MHz (40-587A-001) EN61326-1:2013, Emissions EN55011:2009+A1:2010. Power Requirements +3.3V +12V -12V 130mA (typical) 500mA (typical) 1.3A (max) 70mA (typical) 0 pickeringtest.com 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 1.2...
Page 12
Product Test Tool Adaptor Termination Product Customization 40-584-001 93-002-001 93-002-410 93-002-101 Pickering PXI modules are designed and manufactured on our own 40-585A-001 93-006-001 Not Required 93-006-101 flexible manufacturing lines, giving complete product control and 40-586A-001 93-005-001 Not Required 93-005-101 enabling simple customization to meet very specific requirements.
Page 13
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
Page 14
1-Pole HD Matrix – 40-584/585A/586A/587A Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
MINIMUM SWITCH CURRENT Minimum switch current for models 40-584/585/586A/587A is dependent upon usage. The relay type used in these models has gold plated contacts, a metal that does not tarnish with time and is usually considered well suited for low level switching.
The module comprises a mother board and a daughter board populated with 1-pole electro-mechanical relays configured as a 128x2 (40-584), a 64x4 (40-585A), a 32x8 (40-586A) or a 16x16 (40-587A) matrix. The relays are energised via control signals from relay drivers U11 to U26. Each relay driver is loaded with serial data from PCI bridge U1 to operate the required matrix crosspoint.The main PCI interface circuitry and the drivers and relays that...
Page 17
SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 2.2...
VII. à la Page VII. Ensure that there is adequate ventilation. Assurez-vous que la ventilation est adéquate. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A REED RELAY MODULE 40-110/115/120/125 Page 3.1 Page 3.1...
Page 19
9. Pour l’installation modulaire LXI de Pickering Interfaces, il n’est pas nécessaire d’utiliser une séquence de mise sous tension particulière. Page 3.2 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A REED RELAY MODULE 40-110/115/120/125 Page 3.2...
Pickering Test Panels application. le menu Programs >> Pickering. En l’absence de LabVIEW, le Runtime Engine est nécessaire pour supporter l’application Test Panels de Pickering. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A REED RELAY MODULE 40-110/115/120/125 Page 3.3 Page 3.3...
Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
SECTION 4 - PROGRAMMING PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
PROGRAMMING THE VERY HIGH DENSITY MATRIX The 40-584 is a single pole switching matrix with 128 connections on the X-axis and 2 connections on the Y-axis. Connections are made by operating the relays at the crosspoints between X and Y lines allowing single X-Y connections, or X-X connections using a Y line as a path.
Once the drivers are installed the manual “Sys40Prg.pdf” and driver help files which fully describes these functions can be found in the Pickering folder(s) or the Pickering entries on your Start Menu. The card must be opened before use and closed after using the following function calls: Direct I/O Driver - Open with PIL_OpenCards or PIL_OpenSpecifiedCard and close with PIL_CloseCards or PIL_CloseSpecifiedCards respectively.
Page 25
SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 4.4...
X117 X118 X124 X121 X122 X123 X126 X127 X128 X125 Figure 5.1 - 2 Amp 1-Pole 128x2 Matrix Module 40-584-001: 160-pin DIN41612 Male Connector Pinout (Viewed From Front of Module) 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 5.1...
Page 27
SECTION 5 - CONNECTOR INFORMATION pickering FP_GND Figure 5.2 - 2 Amp 1-Pole 64x4 Matrix Module 40-585A-001: 78-pin D-type Male Connector Pinout (Viewed From Front of Module) 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 5.2...
Page 28
SECTION 5 - CONNECTOR INFORMATION pickering FP_GND FP_GND FP_GND FP_GND FP_GND FP_GND FP_GND FP_GND Figure 5.3 - 2 Amp 1-Pole 32x8 Matrix Module 40-586A-001: 50-pin D-type Male Connector Pinout (Viewed From Front of Module) 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 5.3...
Page 29
SECTION 5 - CONNECTOR INFORMATION pickering FP_GND FP_GND FP_GND FP_GND Figure 5.4 - 2 Amp 1-Pole 16x16 Matrix Module 40-587A-001: 37-pin D-type Male Connector Pinout (Viewed From Front of Module) 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 5.4...
Mises en garde au début du manuel. INSTALLATION PROBLEMS PROBLÈMES D’INSTALLATION The Plug & Play functionality of Pickering switch cards La fonctionnalité Plug & Play des cartes de generally ensures trouble-free installation. commutation Pickering assure généralement une installation sans problème.
OUTILS DE TEST DE SYSTEME DE SWITCHING SYSTEM TEST TOOLS COMMUTATION Please refer to Section 7 - Maintenance Information Référez-vous à la Section 7 - Information sur l’entretien 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 6.2 Page 6.2 REED RELAY MODULE 40-110/115/120/125...
Page 32
à described in the manual for the Modular LXI Chassis. niveau. C’est un processus simple qui est décrit dans le manuel du châssis LXI modulaire. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 7.1...
Page 33
Utilisateurs eBIRST, les outils de test de système de commutation n’ont pas besoin d’utiliser cette fonction pour localiser les relais défectueux. 2 AMP 1-POLE VERY HIGH DENSITY MATRIX 40-584/585A/586A/587A Page 7.2...
Page 46
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the 40-584 and is the answer not in the manual?
Questions and answers