INSTRUCTIONS - CINEMASNAP 235


CONNECT NETWORK CONNECTION
The connect network allows for the connection of up to nine (9) iConnect 240V or 24V

modules.
Connection between modules is via a RJ12 6 Core cable wired straight through.

Connection is made by connecting from the RJ12 connect network out to the RJ12 connect
network in.

A 10 metre RJ12 Connect daisy chain cable is available (Product Code 6500104).

CONTACT CLOSE INPUT

Requires two (2) contacts - one for up command and one for down command.
Contact operation is momentary dry contact, command is sent when contact is reopened

(Lagging Contact)

Contact close input is local only, can be parallel wired to other modules for multiple

control.

Contact close can be reprogrammed to single latched mode by using the 6 button infra red
transmitter if required. (Contact Screen Technics for details)

Two button impulse switches are available (Product Code 3500998)


Contact Close
Input




INTERFACING WITH THIRD PARTY CONTROL SYSTEMS
The iConnect module can be connected to the iReply (Product Code 6500300) interface via the
connect network to provide
RS232 control
RS485 Control
TCP/IP Control
USB Control
(Contact Screen Technics for details.)
FACTORY RESET PROCEDURE
Should you experience problems with the operation of the iConnect module at the time of
installation, a factory reset can be initiated to confirm operational integrity of the iConnect
module.
Infra Red receiver must be connected to the iConnect module
Disconnect module from mains power for 20 seconds
Reconnect module to mains power.
LED on iConnect module will change from green to red (module is now in program mode).
Using the 6 button infra red remote push buttons in the sequence of:
-
Stop 1 - Stop 1 - Stop 2 - Stop 2 - Stop 1 - Stop 1
-
To confirm that the reset was performed the projection screen, AV lifter or roller blind will
jiggle up and down. The module is now reset to factory standard (Infra red operation is
group one (1) and contact close is momentary operation.
Should you have any questions regarding the installation of our projection screens please call
our technical sales desk on +61 2 4869 2100 for assistance.