ACCURATE SPECIFICATIONS
Accuracy: (a% reading + b digits), guarantee for 1 year
Operating temperature: 18℃~28℃
Relative humidity: 75% R.H
Temperature coefficient: 0.1x (specified accuracy)/1℃
Mark
Range
Resolution
400mV
0.1mV
4V
1mV
40V
10mV
400V
0.1V
600V
1V
Input impedance: 10MΩ.
Max input Voltage: 600V DC or 600V AC Peak.
Mark
Conductor
Mark
Accuracy
± (0.8% reading + 2 digits)
± (1.0% reading +2 digits)
10
center the conductor within the
transformer jaw, otherwise it
may cause 1.5% position error