Variably adjustable sample volumes, speed, pause time and AntiDrop function
Automatic initialisation and self-test run
Up to 8 different tube calibrations can be stored and are available in any program
The tube fittings can be exchanged easily thanks to the practical lever closure on the pump head
Self monitoring of all device functions (motors ...)
Easy maintenance, full stainless steel housing
Host PC connection for protocol printing (Optional Recorder Software #700290, Cable#700280)
External printer connection (Optional DosiPrint #750000+Cable #750115)
External control with footswitch (101010)
Benefits:
Ÿ DosiPump allows straight forward dosing directly from the unit main screen.
Ÿ DosiPump allows easy call of any program combined with any previously stored tube value.
Ÿ DosiPump allows to easily editing of even complex dosing-rows in a well arranged spread sheet.
Any individual dosing value can be defined for any individual dose, such as pump direction, pump
speed, pause, anti drop angle repeats e.g.
Ÿ DosiPump accepts tube sizes from 2x6mm for small doses up to a double tube set of 8x12mm for
fast dosing
Ÿ DosiPump is build in a stable stainless steel housing offering IP64 splash water resistance.
DosiPump DP1000 models:
Pump Range: 5ml (1ml +0.1ml steps) - 800ml/min depending tube size
Pump Range: 15ml (1ml +0.1ml steps) -2'400ml/min depending tube size
1.3.4 Symbols used in the User Manual
The signal words WARNING, IMPORTANT and NOTE, used in this User Manual, serve to highlight im-
portant information and instructions applicable to danger situations. These words can be found together
with a special warning symbol in the left-hand column.
Symbol
Definition
Warning points out a potentially dangerous situation which should be avoided in order
to avoid damage to the equipment or injuries. This signal word is used only in extreme
situations and thus requires special attention.
Important points out special problems or important information. Please read through
the accompanying text carefully. It is important for understanding the relevant topic or
command.
Note serves to identify information which is useful but not crucial to a task. Read
though the accompanying text carefully. It may help you to clarify any questions which
you may have.