Battery Charging - Bosch Professional GOS 10,8 V-LI Original Instructions Manual

Digital inspection camera
Hide thumbs Also See for Professional GOS 10,8 V-LI:
Table of Contents

Advertisement

OBJ_BUCH-1311-002.book Page 14 Monday, February 28, 2011 9:32 AM
14 | English
Assembly
Before any work on the inspection camera
itself (e.g. assembling, maintenance, etc.)
as well as when transporting and storing,
remove the battery from the inspection
camera.

Battery Charging

Use only the battery chargers listed on the
graphics page. Only these battery chargers
are matched to the lithium-ion battery used
in your inspection camera.
Note: The battery is supplied partially charged.
To ensure full capacity of the battery, complete-
ly charge the battery in the battery charger be-
fore using your power tool for the first time.
The lithium-ion battery can be charged at any
time without reducing its service life. Interrupt-
ing the charging procedure does not damage the
battery.
The battery is equipped with a NTC temperature
control which allows charging only within a tem-
perature range of between 0 °C and 45 °C. A long
battery service life is achieved in this manner.
Battery Charge-control Indication
When the inspection camera is switched on, the
charge condition of the battery is indicated on
the display 5:
Indication
Capacity
>1/2
<1/2
Reserve
Removing the Battery
To remove the battery 10, press the battery un-
locking buttons 11 and pull the battery toward
the rear out of the inspection camera. Do not
exert any force when doing this.
1 609 929 X35 | (28.2.11)
Mounting the Camera Cable
(see figure A)
For operation of the inspection camera, the cam-
era cable 6 must be mounted to the hand unit 1.
Insert the camera cable 6 into the camera con-
nection 14 in such a manner that the pin of the
camera cable engages into the opening of the
camera connection as shown in the figure. Slide
the socket sleeve 13 on the camera connection
over the camera cable and hand-tighten in clock-
wise direction.
To remove the camera cable 6, unscrew socket
sleeve 13 in anticlockwise direction and pull the
camera cable off.
Mounting the Camera Cable Extension
(Accessory)
To mount a camera cable extension 12, the
mounted camera cable 6 must be removed.
Then, mount the extension 12 onto camera con-
nection 14 as described under "Mounting the
Camera Cable" and tighten.
If required, further extensions can be mounted
in the same manner. However, the image quality
decreases when exceeding a total length approx.
10 m (incl. camera cable).
Screw the camera cable 6 onto the last exten-
sion 12 as described under "Mounting the Cam-
era Cable".
Check if the camera cable and the exten-
sion are firmly connected. The camera cable
and the extension are only water-tight when
firmly connected. Untight connections in-
crease the risk of an electric shock or dam-
age to the inspection camera.
Mounting the Mirror, Magnet or Hook
(see figure B)
The mirror 17, the magnet 15 and the hook 16
can be mounted to the camera head 7 as auxil-
iary aids.
Slide one of the three auxiliary aids to the stop
onto the recess on the camera head 7 as shown
in the figure.