Table 10-1
Power cord requirements for specific countries and regions (continued)
Country/region
India
Israel
Italy
Japan
The Netherlands
New Zealand
Norway
The People's Republic of China
Saudi Arabia
Singapore
South Africa
South Korea
Sweden
Switzerland
Taiwan
Thailand
The United Kingdom
The United States
1.
The flexible cord must be Type HO5VV-F, 3-conductor, 0.75 mm² conductor size. Power cord set fittings (appliance coupler and
wall plug) must bear the certification mark of the agency responsible for evaluation in the country or region where it will be used.
2.
The flexible cord must be Type SVT/SJT or equivalent, No. 18 AWG, 3-conductor. The wall plug must be a two-pole grounding type
with a NEMA 5-15P (15 A, 125 V ac) or NEMA 6-15P (15 A, 250 V ac) configuration. CSA or C-UL mark. UL file number must be on
each element.
3.
The appliance coupler, flexible cord, and wall plug must bear a T mark and registration number in accordance with the Japanese
Dentori Law. The flexible cord must be Type VCTF, 3-conductor, 0.75 mm² or 1.25 mm² conductor size. The wall plug must be a
two-pole grounding type with a Japanese Industrial Standard C8303 (7 A, 125 V ac) configuration.
4.
The flexible cord must be Type RVV, 3-conductor, 0.75 mm² conductor size. Power cord set fittings (appliance coupler and wall
plug) must bear the CCC certification mark.
5.
The flexible cord must be Type H05VV-F 3-conductor, 0.75 mm² conductor size. KTL logo and individual approval number must
be on each element. Approval number and logo must be printed on a flag label.
6.
The flexible cord must be Type HVCTF 3-conductor, 1.25 mm² conductor size. Power cord set fittings (appliance coupler, cable,
and wall plug) must bear the BSMI certification mark.
7.
For 127 V ac, the flexible cord must be Type SVT or SJT 3-conductor, 18 AWG, with plug NEMA 5-15P (15 A, 125 V ac), with UL and
CSA or C-UL marks. For 240 V ac, the flexible cord must be Type H05VV-F 3-conductor, 0.75 mm² or 1.00 mm² conductor size,
with plug BS 1363/A with BSI or ASTA marks.
78
Chapter 10 Power cord set requirements
Accredited agency
BIS
SII
IMQ
JIS
KEMA
SANZ
NEMKO
CCC
SASO
PSB
SABS
KTL
SEMKO
SEV
BSMI
TISI
ASTA
UL
Applicable note number
1
1
1
3
1
1
1
4
7
1
1
5
1
1
6
1
1
2