Accessing Basic Menu Items - Navien NFC-175 Installation & Operation Manual

Nfc condensing combi-boilers
Hide thumbs Also See for NFC-175:
Table of Contents

Advertisement

11.3 Accessing Basic Menu Items

In the Main Menu screen, you can view the boiler's operating
conditions, configure the space heating and DHW temperatures,
and review error history. Press the Menu button (
Main Menu screen.
11.3.1 Quick Setup Menu
The Quick Setup Menu is designed to help configure the boiler
settings after installation is complete. To enter the Quick Setup
Menu, press the Menu button (
Menu". Press the Back button (
Item
1. Outdoor Reset
ON/OFF
1-1. Outdoor Reset
Curves
1-2. Outdoor High
Temp Set
1-3. Outdoor Low
Temp Set
1-4. WWSD Temp
2. Auto-Fill Pressure
3. Time Setting
4. DHW Recirculation
88
Operating the Boiler
) to enter the
), and select "1.Quick Setup
) to return to the previous screen.
Description
Set the Outdoor Reset Control settings.
Set the Outdoor Reset Curve when the
Outdoor Reset is used.
Set the maximum value for the Outdoor
Reset Control when the Outdoor Reset
is used.
Set the minimum value for the Outdoor
Reset Control when the Outdoor Reset
is used.
Set the WWSD temperature.
Set the Auto-Fill Pressure.
Set the system clock (RTC).
Display format: YYYY.MM.DD /
HH:MM:SS
Set the DHW Recirculation type setting.
11.3.2 Viewing Basic Information
To view information about the boiler, press the Menu button (
and then select "2. Status Information".
Rotate the Command dial (
items. Press the Command dial (
information.
Press the Back button (
) to exit information view mode.
Item
1. Operation State
Current Operation State
2. Heat Capacity
Heat Capacity (%)
3. SH Set Temp
Space heating set temperature (°F)
4. DHW Set Temp
DHW set temperature (°F)
5. Supply Temp
Heating supply temperature (°F)
6. Return Temp
Boiler return temperature (°F)
7. Sys Supply Temp
System supply temperature (°F)
8. Sys Return Temp
System return temperature (°F)
9. Outlet 1 Temp
Heat exchanger outlet temperature (°F)
10. Outlet 2 Temp
Outlet temperature (°F)
11. Inlet Temp
Inlet temperature (°F)
12. Outdoor Temp
Outdoor temperature (°F)
13. Approx. Boiler
SH flow rate (GPM)
Flow
14. DHW Flow
DHW flow rate (GPM)
15. Water Press
Water pressure (psi)
Flame detector AD value
Flame On: 8bit AD values equal to or
16. Flame Value
lower than 70
Flame Off: 8bit AD values equal to or
higher than 175
) to switch between the information
) to select an item and view the
Description
),