8. Installing a Cascade System

When installing a cascade system, carefully consider the design of the system and the features of the installation location. Follow all local
codes and regulations, as well as all guidelines for installing the combi-boiler and water heaters. The following sections describe additional
considerations that are specific to installing cascade systems. Read them carefully before designing or installing the system.

8.1 Connecting Water Supplies

Several options are available for applying a cascade system of combi-boilers and water heaters. The options shown here are only examples.
The setup you choose will vary based on the installation location, local building codes, and other factors. Follow all applicable regulations
when installing a cascade system.
You can connect up to 1 combi-boiler and 15 Navien water heaters (NPE model) to meet high-volume heating demands. Some possible
connection options include the following:
Example of a Basic Cascade System Application
Heating
Supply
Pump
Air Separator with
Expansion Tank
Heating Return
System application drawings are intended to explain the system piping concept only.
Note
Install a NaviClean Filter in the system heating return to remove foreign objects from the system. Foreign objects inside the
system may result in abnormal system operation.
Refer to "3.4 Filling the System" on page 28 for make-up water connections and refer to the requirements of your local codes
to ensure compliance.
Use pumps with integral check valves or install check valves at the pump outlets.
Adjust the settings at the main unit as the cascade system uses only the main unit settings. Changes made to the sub units are
ignored.
Pressure
Relief Valve
Air Vent
Main
NaviClean
Optional System
Temperature Sensor
<NPE Series>
Sub1
Ball Valve
Faucet
[NFC-175/200]
<NPE Series>
Sub2
Ball Valve
Check Valve
Installing a Cascade System
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nfc-200

Table of Contents