Outdoor
Capacity
HP
(100W)
68
1908
Combination (450+450+504+504)
70
1962
Combination (450+504+504+504)
72
2016
Combination (504+504+504+504)
74
2072
Combination (504+504+504+560)
76
2128
Combination (504+504+560+560)
78
2184
Combination (504+560+560+560)
80
2240
Combination (560+560+560+560)
82
2295
Combination (560+560+560+615)
84
2350
Combination (560+560+615+615)
86
2405
Combination (560+615+615+615)
88
2460
Combination (615+615+615+615)
Note:
a. If all the indoor units operate at the same time in one system, the total indoor units capacity should be less
than or equal to the total outdoor units capacity. Otherwise,overloading operations may occur in bad operating
condition or some special conditions. If all the indoor units don't operate at the same time in one system,the total
indoor units capacity should be no more than 130% of the total outdoor units capacity.
c. If the system operates in high heat load or cold area (Ambient Temperature below -10°C), the total indoor units
capacity should be less than the total outdoor units capacity.
d. To choose combinations' wires and air switches according to the Max. operating current of the combinations.
Installation place selection
Air-conditioner can't be installed in the
place with inflammable gas. Or it will
cause fire hazard.
The unit should be installed at the
place where the cold/hot air or
noise will not interfere the neighbours.
Combination type
The unit should be installed at the
place with good ventilation. No
obstacle at the air inlet/outlet. And no
strong wind blows the unit.
The installation space refers to the
latter info.
• The place where the water can flow
fluently.
• The place where no other heat
source will affect the unit.
• Pay attention to the snow against
clogging the outdoor.
• In installation, install the anti-
vibration rubber between the unit
and the bracket.
Indoor
Indoor Qty
Total indoor capacity (HP)
1~64
34~88.4
1~64
1~64
36~93.6
1~64
37~96.2
1~64
38~98.8
1~64
39~101.4
1~64
40~104
1~64
41~106.6
1~64
42~109.2
1~64
43~111.8
1~64
44~114.4
The unit should be installed at
the strong enough place. Or it will
cause vibration and noise.
• The unit is better not be installed
• The place where there is
• The place blowing salty air
• Exsits the strong coal smoke.
• The place with high humidity.
• The place where there is device
• The place where voltage
66
Gather pipe
35~91
HZG-R40B
at the below places, or it will
cause damage.
corrosive gas (spa area etc).
(seaside etc).
emitting Hertzian waves.
changes greatly.