= (N
x BV) / Q
slow rinse
BVsr
To calculate fast rinse duration:
The fast rinse is aimed at eliminating an excess of salt in the resin bed and also recompacting the
resin in the tank.
Depending on the valve type, the fast rinse flow rate is controlled by the DLFC or it has about the
same flow rate as in service. The fast rinse velocity can be the same as the service velocity, and
the volume of water to be used for the fast rinse is generally between 1 and 10 BV depending on
the salt dosage.
T
= (N
x BV) / Q
fast rinse
BVfr
To calculate the refill duration:
The refill flow rate is controlled by the refill controller (BLFC). The relation between the BLFC
size, the tank size and the resin volume is given in the valve specifications.
To calculate the refill duration:
T
= V
/ Q
refill
WB
BLFC
V
= D
x BV / S
WB
Salt
sol
Tip
When calculating the time required to draw the brine, take into account that the volume
of brine [Vbrine] will be 1.125 bigger than the volume of water refilled !
Ref. MKT-IM-005 / F - 30.04.2020
with:
SR
T
N
BV: bed volume [L]
Q
with:
DLFC
T
N
BV: bed volume [L]
Q
with:
T
V
[L]
Q
with:
V
[L]
D
BV: Bed volume [L]
S
Installer manual Fleck 5800 LXT - System sizing
: slow rinse duration [min]
slow rinse
: number of bed volume for slow rinse
BVsr
: injector slow rinse flow rate [L/min]
SR
: fast rinse duration [min]
fast rinse
: number of bed volume for fast rinse
BVfr
: drain line flow controller size [L/min]
DLFC
: refill duration [min]
refill
: Volume of water to be refill to prepare the brine
WB
: BLFC size [L/min]
BLFC
: Volume of water to be refill to prepare the brine
WB
: Salt dosage per litre of resin [g/L]
Salt
: 360g/L - Solubility of salt per litre of water
sol