Onu Replacement Procedure - Nokia 7368 ISAM ONT E-240G-B Product Manual

Intelligent services access manager
Table of Contents

Advertisement

7368 ISAM ONT E-240G-B Product Guide

7.6 ONU replacement procedure

Use this procedure to replace an E-240G-B ONU.
1
2
3
Figure 37
E-240G-B ONU connections
Ground lug
4
Issue: 01
Release 06.01.01 | June 2019 | Edition 09
Deactivate the ONU services at the P-OLT.
If you are using the SLID feature, this step is not required. The ONU and the services can
remain in service (IS).
i
Use the RTRV-ONU command to verify the ONU status and the associated services.
Record the serial number or the SLID of the ONU displayed in the command output.
Example:
RTRV-ONU::ONU-1-1-1-1-1;
ii
If the ONU is in service, place the ONU in OOS state.
Example:
ED-ONU::ONU-1-1-1-1-1;
Power down the ONU by using the ON/OFF power switch.
Disconnect the POTS, Ethernet, power, and ground cables, if required, from the ONU; see
Figure 37.
POTS 1
POTS 2
DATA 1
DATA 2
POTS ports
Gigabit Ethernet
(RJ-14)
ports (RJ-45)
Unplug the SC/APC fiber optic cable from the ONU.
i
Loosen the lock screw on the fiber optic connection clip.
ii
Lift the connection clip up.
iii
Unplug the fiber optic cable with SC/APC adapter from the fiber optic connector located
on the back of the E-240G-B ONU as shown in Figure 37.
iv
Lower the clip and tighten the lock screw.
3FE-46261-AAAA-TCZZA
DATA 3
DATA 4
POWER
ON/OFF
On/off
Power
button
connector
Replace an E-240G-B ONU
SC/APC
connector
24108