■ Power Supply and Water Supply
Please use power socket with 15 amp AC
220-240V, 50 Hz and Min. power 650W.
Power cord length is 1.0 m.
As per the below diagram the power supply should sit
300mm from finished floor and appropriate distance from
water supply.
Ensure that socket earth wire is connected correctly,
otherwise, contact electrical installation company to
perform work.
Do NOT plug into power until installation is complete!
Risk of electric shock if power supply not grounded. Power supply grounded here indicates that the
ground wire of distributor uses copper wire with a diameter of 1.5 mm or more when ground resistance
is less than 100 Ω.
Only to be used with clean potable water.
Water pressure supplied should be maintained between 0.06 MPa (0.6 kgf/cm
0.75 MPa (7.5 kgf/cm
Note: It is a requirement of Australian regulators that the water supply to this product must be protected by a high hazard
backflow prevention device, such as a reduced pressure zone device (RPZD). As per AS/NZS 3500.1, the RPZ shall be
maintained in working order and tested for operational functions at intervals not exceeding 12 months.
Any electrical work connected to this product must be installed by qualified personnel in accordance with AS/NZS 3000