Functional Overview - Panasonic MINAS A6 Quick Start Manual

Position control by block operation using modbus commands
Hide thumbs Also See for MINAS A6:
Table of Contents

Advertisement

2 Functional overview

2
Functional overview
Position control is a control mode in which the motor moves the load to a specified target
position.
The servo driver can be controlled by a pulse train in the frequency range between 1Hz and
8MHz from a host controller such as a PLC or a CNC controller or by block operation. With
block operation, the user defines the positioning parameters in command blocks. The MINAS
A6 servo driver has a block memory capacity of 256 command blocks. All command blocks
are saved in a block operation table in the servo driver.
Block operation table
You can set the command blocks using the PANATERM configuration software or by Modbus
commands if you are using a PLC with a Modbus RTU communication interface. The
command blocks are either started by digital signals (e.g. STB, B-SEL1 to B-SEL128) from a
PLC, a trigger switch, or by Modbus commands.
This Quick Start Guide explains how to wire and configure the servo driver for block
operation using Modbus commands.
Example
An FP0H PLC and a MINAS A6SF servo driver are connected to control the driver by
Modbus commands.
Data transmission between PLC with Modbus RTU interface and servo driver via serial
communication cable
6
QS2002_V1.0_EN

Advertisement

Table of Contents
loading

Table of Contents