Download Print this page

STUDIO DUE MP Maxi Power Series User Manual

Modular system monochromatic

Advertisement

Quick Links

monochromatic
User manual for art. 1811-1812-1814-1815-1818
Manuale d'uso per art. 1811-1812-1814-1815-1818

Advertisement

loading
Need help?

Need help?

Do you have a question about the MP Maxi Power Series and is the answer not in the manual?

Questions and answers

Summary of Contents for STUDIO DUE MP Maxi Power Series

  • Page 1 monochromatic User manual for art. 1811-1812-1814-1815-1818 Manuale d’uso per art. 1811-1812-1814-1815-1818...
  • Page 2 Elevata immunità ai sovraccarichi di tensione grazie all’utilizzo di un Modulo di Protezione contro le Sovra- tensioni 10KV-20KA in grado di sopportare impulsi di tensione e corrente fino a 10.000 Volt e 20.000 Am- pere. rel. 11_1/18 - Studio Due...
  • Page 3 Page 13 - DRS Setup configuration / Configurazione DRS Setup Page 16 - Physical / Dimensioni Page 17 - CE standards / Certificazioni CE Page 19 - Warranty / Garanzia MP Maxi Power 240 MP Maxi Power 120 MP Maxi Power 60 rel.11_1/18 - Studio Due...
  • Page 4 2) La temperatura dell’apparecchio può raggiungere 75°C. 3) Gli schermi di protezione e le lenti devono essere sostituiti sempre con ricambi originali se sono visibilmente danneggiati e se la loro efficacia è stata ridotta, per esempio, da fessure o incisioni profonde. rel. 11_1/18 - Studio Due...
  • Page 5 • IP65 POWERCON Male connector (without cable) • IP65 XLR 5pins Male and Female connectors (without cable) • User manual • Studio Due warranty • CE standards WARNING Check that the fixture has not been damaged during transport. If it has been damaged or it does not work, address the seller.
  • Page 6 Surge Protection 10KA, 20KV max (Differential and Common mode Protections) * Voltage Range 180-240Vac; 47-65Hz Gear Unit N.1x 600W Power Consumption 580W Inrush Current 60A (230Vac) Power Factor (PFC) >0,95 Operating Temperature -20° to +40° Physical 672x204x569mm Weight 33 Kg rel. 11_1/18 - Studio Due...
  • Page 7 Surge Protection 5KA, 10KV max (Differential and Common mode Protections) * Voltage range 180-240Vac; 47-65Hz Gear unit N.1x 150W Power consumption 145W Inrush current 40A (230Vac) Power Factor (PFC) >0,95 Operating temperature -20° to +40° Physical 362x206x320mm Weight 8,6 Kg rel.11_1/18 - Studio Due...
  • Page 8 100-240V.~ / 50-60Hz SIGNAL Line Neutral Ground MAIN OUT MAIN IN Uscita rete Ingresso rete MAIN IN POWERCONN MAIN OUT POWERCONN IP65 connector IP65 connector (endower) (optional) close the caps when these connections are not used rel. 11_1/18 - Studio Due...
  • Page 9 120 Ohm DMX output DMX output DMX input DMX input Termination resistor Terminale di linea SHIELD GROUND/RETURN/OV Termination resistor 120 Ohm Terminale di linea INNER CONDUCTOR DATA TRUE ( +, NON INVERTED) rel.11_1/18 - Studio Due...
  • Page 10 FLASH 0,4Hz / 25Hz RAINBOW - FLASH 0,4Hz / 25Hz OPEN STROBE 128 -255 2 -127 0 - 1 LED FADE FAST - 0,1 sec. SLOW 0 = CUT TIME LINEAR 25,5 sec. 8 BIT FUNCTION DIMMER rel. 11_1/18 - Studio Due...
  • Page 11 * DMX CONNECTION ** DALI CONNECTION * CONNESSIONE DMX ** CONNESSIONE DALI DMX CONNECTION DALI CONNECTION SIGNAL SIGNAL GROUND DALI 1 DATA COMPLEMENT (-, inverted) DALI 2 DATA COMPLEMENT (+, not inverted) MP60 and MP120 connections MP240 connections rel.11_1/18 - Studio Due...
  • Page 12 / fixture / fixture / fixture / fixture / fixture / apparecchio apparecchio apparecchio apparecchio apparecchio apparecchio apparecchio fixture 1 fixture 3 fixture 4 fixture 2 fixture 3 fixture 4 fixture 1 fixture 2 rel. 11_1/18 - Studio Due...
  • Page 13: Main Power

    E’ possibile assegnare agli apprecchi collegati i canali DMX o utilizzazre la funzione Master/Slave. Il DRS è alimentato a batterie. DMX line XRL - LLT connector Powered through battery MAIN Power RDM console rel.11_1/18 - Studio Due...
  • Page 14 • Il pulsante ENTER permettere di entrare in un menu o di confermare una opzione in caso di lampeggio del parametro • Il pulsante ESC annulla una operazione o torna al livello di menu inferiore. rel. 11_1/18 - Studio Due...
  • Page 15 (OFF, On) Reset (rSEt) Execute a reset of the electronic section Esegue un reset della parte elettronica Format (FrMt) Restore the factory setting (Require confirmation) Ripristina le impostazioni di fabbrica (Viene chiesta conferma) rel.11_1/18 - Studio Due...
  • Page 16 450,00 674,00 310,00 257,12 95° 0° 95° 45° + 20° 535,00 0° - 5° MP Maxi Power 120 45° - 5° + 20° 95° 95° 307,00 0° 0° 45° 45° MP Maxi Power 60 rel. 11_1/18 - Studio Due...
  • Page 17 Monochromatic series 09/2018 Dichiarazione di conformità Declaration of conformity La ditta: STUDIO DUE light s.r.l. The firm: Strada Poggino, 100 01100 VITERBO ITALY dichiara sotto la propria responsabilità che il prodotto: declare under our sole responsability that the product: MP60 - MP120 - MP240 - Maxi Power MONOCHROMATIC IP65 series code 1811 - 1812 - 1814 - 1815 - 1818 (all versions) è...
  • Page 18: Warranty Card

    Tutte le apparecchiature godono della garanzia di un anno contro difetti di fabbricazione o di materiali, sono esclusi dalla garanzia danni derivanti da un cattivo uso o installazione delle apparecchiature. Le lampade restano comunque escluse dalla garanzia. Per ogni controversia è competente il Foro di Viterbo. rel. 11_1/18 - Studio Due...
  • Page 19 / questa pagina è stata lasciata intenzionalmente bianca rel.11_1/18 - Studio Due...
  • Page 20 Head Office: STUDIO DUE s.r.l. (I) Str. Poggino, 100 - 01100 Viterbo (Italy) tel. +39.0761.352520 fax +39.0761.352653 info@studiodue.com STUDIO DUE (UK) 3 Encon Court Owl Close Moulton Park Industrial Estate Northampton England UK - NN3 6 HZ tel. +44.1933.650.820 info@studiodue.co.uk www.studiodue.com...