Download Print this page

Advertisement

Quick Links

rgbw/fc
User manual for art. 1519 and art. 1518
Manuale d'uso per art. 1519 e art. 1518

Advertisement

loading
Need help?

Need help?

Do you have a question about the ARCHIBAR-SL300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STUDIO DUE ARCHIBAR-SL300

  • Page 1 rgbw/fc User manual for art. 1519 and art. 1518 Manuale d’uso per art. 1519 e art. 1518...
  • Page 2 INDOOR USE ONLY these CONNECTORS CONNECTORS art. AMPHENOL/XRL MF male/female connectors are for INDOOR use are IP67 (optional) only art. AMPHENOL/XRL MF connettori maschio/femmina questi connettori sono questi connettori (opzionale) solo per uso INTERNO sono IP67 rel.3 - 02/17 - Studio Due...
  • Page 3 Click on the QR Code with your smartphone to go directly to the web- site Clicca sul codice QR con il tuo smartphone per accedere direttamente al sito web ARCHIBAR SL200 rgbw/fc (art. 1518) rel.3 - 02/17 - Studio Due...
  • Page 4 3) Gli schermi di protezione e le lenti devono essere sostituiti sempre con ricambi originali se sono visibilmente danneggiati e se la loro efficacia è stata ridotta, per esempio, da fessure o incisioni profonde. rel.3 - 02/17 - Studio Due...
  • Page 5: Basic Kit

    Se avesse subito dei danni o se non dovesse funzionare, rivolgetevi al vostro rivenditore. Se l’apparecchio vi è stato spedito direttamente, rivolgetevi subito alla ditta di trasporto. Solo il destinatario (la persona o ditta ricevente l’apparecchio) può reclamare per questo tipo di danni. rel.3 - 02/17 - Studio Due...
  • Page 6 WxDxH: 928 x110x93 mm (dimension of profile) WxDxH: 928 x110x93 mm (dimension of profile) Weight: 6,7 Kg. Weight: 6 Kg. on request: 600, 1200 and 1500 mm lenght on request: 600, 1200 and 1500 mm lenght rel.3 - 02/17 - Studio Due...
  • Page 7 9ch set-up 9ch set-up 9ch set-up 9ch Set up = MASTER =C001 =C010 =C019 =C027 Terminal Line fixture 1 fixture 2 fixture 3 fixture 4 fixture 1 fixture 2 fixture 3 fixture 4 rel.3 - 02/17 - Studio Due...
  • Page 8 Main IN Main IN PoWER InPuT/ InGRESSo ALIMEnTAzIonE ø 6 - 12mm CONDUCTOR SIZES / SEZIONE CONDUTTORE (length / lunghezza < 20mt.) MAInS VoLTAGE CRoSS SELECTIonAL AREAS MAIn In/ouT Ingresso/uscita rete 230V 3X1 mm (minimum) rel.3 - 02/17 - Studio Due...
  • Page 9 Termination resistor Terminale di linea GROUND/RETURN/OV N.C. SHIELD GROUND/RETURN/OV DATA COMPLEMENT ( -, INVERTED) Termination resistor 120 Ohm Terminale di linea DATA TRUE ( +, NON INVERTED) INNER CONDUCTOR DATA TRUE ( +, NON INVERTED) rel.3 - 02/17 - Studio Due...
  • Page 10 ENTER >> UP >> DOWN >> ESC DMX led UNLOCK sequence DOWN ENTER 1° 2° 3° 4° 1--- / -2-- / --3- / ---4 To enter the menu Per entrare nel menù ESC / UP / DOWN / ENTER rel.3 - 02/17 - Studio Due...
  • Page 11 All’accensione, viene visualizzato il modello di apparecchio e la versione software. Per esempio: --> Studio Due Archibar --> 1_1 0 --> DMX channel --> C001 than it’s shown the first DMX channel. When you press any button it’s shown the first menu.
  • Page 12 > Selezionate il colore con i tasti uP/DoWn. Premere EnTER. white > Select the value 0 .. 255 with the uP/DoWn buttons. Don’t press EnTER. > Selezionate il valore desiderato 0 .. 255 con i tasti uP/DoWn. non premere EnTER. white balance rel.3 - 02/17 - Studio Due...
  • Page 13 > Select the value off >> RGB or on >> CYM with the uP/DoWn buttons. Press EnTER. > Selezionate il valore desiderato off >> RGB or on >> CYM con i tasti uP/DoWn. Premere EnTER. rel.3 - 02/17 - Studio Due...
  • Page 14 > Select the value f1 .. f2 with the uP/DoWn buttons. Press EnTER. > Selezionate il valore desidarato f1 .. f2 con i tasti uP/DoWn. Premere EnTER. (ntc) Service personnel only / Solo personale di servizio rel.3 - 02/17 - Studio Due...
  • Page 15 CH4: White CH4: White DMX Channels list 9Ch / Lista dei canali DMX 9Ch GREEN BLUE WHITE 2-127 128-255 Strobe Open Dimmer 0=CUT LINEAR fade time FAST SLOW Rainbow 0-15 16-255 Balanced white normal rel.3 - 02/17 - Studio Due...
  • Page 16 DMX Channels list 4Ch / Lista dei canali DMX 4Ch GREEN BLUE WHITE STuDIoDuE light s.r.l. str. Poggino, 100 - 01100 VITERBo ITALy - tel. +39 0761 352520 - fax +39 0761 352653 http://www.studiodue.com E-Mail: info@studiodue.com - service@studiodue.com rel.3 - 02/17 - Studio Due...
  • Page 17 RAINBOW FAST Preset 13 WHITE BALANCE (from cool) to ..Preset 18 WHITE BALANCE (to warm) Preset 19 SIMULATION SODIUM lamps (yellow type) to ..Preset 24 SIMULATION SODIUM lamps (yellow type) rel.3 - 02/17 - Studio Due...
  • Page 18 ARCHIBAR SL300 - PHYSICAL / DIMENSIONI rel.3 - 02/17 - Studio Due...
  • Page 19 ARCHIBAR SL300 - PHYSICAL / DIMENSIONI rel.3 - 02/17 - Studio Due...
  • Page 20 ARCHIBAR SL200 - PHYSICAL / DIMENSIONI rel.3 - 02/17 - Studio Due...
  • Page 21 Direttive: and therefore according to essential requirement of Directives: LV 73/23 AND 93/68 EEC EMC 89/336 AND 93/68 EEC Data di apposizione Date of marking PAOLO SENSI General Manager VITERBO, 30/06/2015 rel.3 - 02/17 - Studio Due...
  • Page 22 Direttive: and therefore according to essential requirement of Directives: LV 73/23 AND 93/68 EEC EMC 89/336 AND 93/68 EEC Data di apposizione Date of marking PAOLO SENSI General Manager VITERBO, 29/07/2015 rel.3 - 02/17 - Studio Due...
  • Page 23: Warranty Card

    Tutte le apparecchiature godono della garanzia di un anno contro difetti di fabbricazione o di materiali, sono esclusi dalla garanzia danni derivanti da un cattivo uso o installazione delle apparecchiature. Le lampade restano comunque escluse dalla garanzia. Per ogni controversia è competente il Foro di Viterbo. rel.3 - 02/17 - Studio Due...
  • Page 24 Head Office: STUDIO DUE s.r.l. (I) Str. Poggino, 100 - 01100 Viterbo (Italy) tel. +39.0761.352520 fax +39.0761.352653 info@studiodue.com STUDIO DUE (UK) 3 Encon Court owl Close Moulton Park Industrial Estate northampton England uk - nn3 6 Hz tel. +44.1933.650.820 info@studiodue.co.uk...

This manual is also suitable for:

Archibar-sl200