Troubleshooting; Maintenance; Disposal - Cedes GridScan/Pro Installation And Operation Manual

Hide thumbs Also See for GridScan/Pro:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GridScan/Pro

12. Troubleshooting

Rx LED
Tx LED
Green
Green
LED off
LED off
LED off
LED off
LED green
LED green
LED off/on
LED off
(flickering green)
LED green
LED off
LED green
LED on/off
(flickering green)
LED green
LED off
LED off
LED off
LED green
LED off
Important: Whenever a parameter is changed, the system must be restarted.
If a problem persists, please contact your local CEDES representative. Visit www.cedes.com for contact data.

13. Maintenance

Although the GridScan/Pro does not need regular
maintenance, a periodic functional check is strongly
recommended:
` Make sure the optical elements are clear of dirt and dust.
If necessary, clean the front surface with a soft towel.
` Make sure the edges are securely fastened.
` Check the mounting position, cable routing and
connection of the sensor.
NOTICE
Damage to the optical elements
 Never use any solvents, cleaners or mechanically
abrasive towels or high-pressure water to clean
the sensor.
 Avoid scratching the optical elements while
cleaning.
© CEDES | V 1.0
Rx LED
Red
Action
LED off
` Check electrical connections.
` Check supply voltage of the door controller.
LED red
` Check the connection of the synchronization cable.
LED off
` Make sure the sensor edges are not mounted close to any
shiny or reflective surface.
` Restart the system.
LED off/on
` Check power supply.
(flickering red)
` Check connections.
LED off/on
` Make sure the safeguarded area is clear of interruption.
(slow blinking red)
` Check the alignment of the light curtain.
` Clean elements.
LED off/on
` Make sure the safeguarded area is clear of interruption.
(flickering red)
` Clean the elements.
` Make sure that the cables and edges are located away from
sources of electromagnetic interference.
` Ensure that the emitter and receiver are correctly aligned
and remain so during door closure (e.g. that vibrations do
not cause edges to become misaligned).
` Restart the system.
LED red
` Make sure the safeguarded area is clear of interruption.
` Reopen door completely.
` Clean the elements.
` Check the alignment of the light curtain.
` Check that the test input is connected to the test output
signal of the door control unit and that the signal level and
logic (HIGH/LOW) are correct. If the test input is not used,
connect it permanently to U
` Measure the U
` Restart the system.
LED off/on
` Check the connection of the synchronization cable.
(slow blinking red)
Internal error occurred
LED off/on (red,
fast blinking, 5 Hz)
` Restart the system.
` Replace Rx edge.

14. Disposal

The GridScan/Pro should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful materials
used in the design and manufacture of the sensor. Traces
of such dangerous materials may be found in the electronic
components but not in quantities that are harmful.
.