Troubleshooting; Key Combination - Nemox Crea Series Instruction Book

Table of Contents

Advertisement

Available languages

Available languages

avoid developing resistant forms of
bacteria. Bacteria spores are the most
resistant biological forms and, therefore, it
is recommended you use chloride-based
products.

TROUBLESHOOTING

•Machine does not cool:
•Check that the power plug is properly
inserted and the appliance has electrical
energy.
•The safety device of the compressor comes
into action: wait 5-10 minutes before
restarting the machine. Rapid and continued
start-up attempts do nothing but prolong the
period of inactivity of the machine.
•Check that the machine is correctly
positioned with the ventilation grids (6) free of
any obstructions.
•Check that the machine is not running a
preservation cycle (LED (11a,b,c,d) flashing)
that stops the compressor.
•Check that when the machine (switch (10))
turns on, the control panel shows the correct
initialization procedure by turning on all LEDs
in sequence.
•The paddle does not turn:
•Check that the paddle (5) is properly
attached to the tube and locked with a
special locking ring (4).
•Make sure it is free from obstacles that
prevent it from rotating.
•Make sure the lid is closed in the correct
position: a safety device stops the paddle
when the lid is opened.
•Check that the LED paddle (2a) is not
BLADE ACTIVATION
COMPRESSOR ACTIVATION
PROGRAM ACTIVATION
PRESERVATION ACTIVATION
TURN OFF FROM PROGRAM
TURN OFF FROM PRESERVATION
PROGRAM CHANGE
PRESERVATION CHANGE
PROGRAM ACTIVATION FROM PRESERVATION*
PROGRAM ACTIVATION FROM PRESERVATION***
* If preservation is activated after a program.
** To activate the program whose LED is flashing, first select a different program.
*** If conservation is activated without running programs.
14
English
ACTION
flashing. In this case, press the button (2)
twice to restart the paddle. Make sure that
the mixture is not too thick to prevent the
rotation of the paddle.
•Make sure that the machine is not running a
preservation cycle (LEDs (11a-b-c-d)
flashing) that stops the paddle.
•The machine is noisy:
•Some noise is part of the normal operating
specifications, but if it becomes excessive
contact the Service Centre to avoid further
and more serious problems.
•The water discharge pipe leaks:
•Replace the gaskets of the water discharge
tap (9). Two additional gaskets sets (16) are
provided with the machine. Lubricate the
gaskets before fit the tap (9) into the water
discharge tube.
•The plastic sleeve (17) on the lower part of the
paddle is tto easy to separate.
•Replace the gasket with the new one. Four
additional gasket (15) are provided with the
machine.
•The paddle does not scrape properly the sides
of the bowl.
•Check that the scrapers (18) and (19) are not
damaged or worn. An additional set is
provided with the machine.
•Check that the resilient pads (20) are not
distorted. If they are distorted replace them.
An additional set is provided with the
machine.

KEY COMBINATION

2
1
11
1+2 (3 seconds)
11 (3 seconds) then 1 and 2
11 (3 seconds)
11
12
11**
11