XM Factory Test
Testing of XM function.
For more information
refer section 8.2.4.
8.2.3.
CD Self-Adjustment (AJST) Result Display
Purpose : To check the result of self-adjustment for CD.
Below is the procedures for this mode.
Step 1: Enter into Doctor mode.
(For more information, refer to section 8.2 on key operation to enter into this mode).
Step 2: Press [
], [1], [4] button on remote control. It enter into CD Self-Adjustment Test mode. (During this mode the result shall
correspond to the condition as shown in the table below).
8.2.4.
XM Factory Test
Purpose : To check XM function.
Below is the procedures for this mode.
Step 1: Enter into Doctor mode (For more information refer to section 8.2 on key operation to enter into this mode).
Step 2: Press [REPEAT], [CLEAR], [PROGRAM] button on remote control. Enter XM testing.
· Testing of XM function during factory mode can be executed as below:
Step
Checking Item
1
Plug in test box and
ART20
2
Power On Set
3
Enter Factory Mode
4
Power up Checking
FL Display
Key operation
-
-
Press power ON button
-
Long press [STOP] main set
-
+ (remote [4] and then [7])
Press [REPEAT] button on
Test Box
remote control. To exit,
Press [
] button on main
unit or remote control.
Key Operation
Front Key
1.
In doctor mode:
1. Press [REPEAT] button on remote control.
To exit Doctor Mode, press
main unit or remote control.
2.
In doctor mode:
2. Press [CLEAR] button on remote control.
To exit Doctor Mode, press
main unit or remote control.
3.
In doctor mode:
3. Press [PROGRAM] button on remote control.
To exit Doctor Mode, press
main unit or remote control.
Device
-
Normal Display
Factory Mode Display