b.
Reverse the Spray Tip to UNCLOG
position, pull the Sprayer Trigger
for 30 to 60 seconds until sprayer
is clean. Release the Sprayer
Trigger.
NOTICE
Do not run sprayer without fluid. Running
sprayer dry will cause damage to the
pump.
13. Do not store sprayer with water in pump.
To remove all water prior to storage:
a.
Remove cup assembly from
sprayer.
b.
Turn Prime Pump/Spray Knob
downward to PRIME position.
c.
Pull Sprayer Trigger for 5 seconds
d.
Disconnect power (unplug Power
Cord).
14. Remove cup assembly from sprayer.
Separate Cup Lid from Cup Support and
pour unused water into waste bucket.
15. Dispose of the fluid in the waste bucket
according to the instructions on the
disinfectant container label and
applicable regulations.
3A7646C
Cleanup and Storage
16. Remove Spray Tip, Spray Tip Guard,
and Pump Filter from sprayer. Clean with
warm water. A soft brush can be used if
needed.
17. Use a soft cloth to clean the Cup
Support, Cup Lid and sprayer.
Do not allow water to freeze in sprayer.
Do not store sprayer under pressure.
Confirm the Prime Pump/Spray Knob is
downward in PRIME position.
Store sprayer in an upright position only.
Store sprayer indoors in a cool, dry
place.
Store Spray Tip, Spray Tip Guard, and
Pump Filter with sprayer so they are
available for the next job.
ti23372a
ti29755a