7.3 Multi-function button

Fig. 33: Multi-function button
The multi-function button has several functions:
A
Terminating an on-going charging process (only for
charging stations without authorisation) and
acknowledging of errors.
Re-activating the residual current circuit breaker (RCCB)
B
and / or circuit breaker (CB) in case of failure.
Triggering the test-function of the residual current
C
circuit breaker (RCCB).

7.3.1 Terminating an on-going charging process

Press the multi-function button to terminate a charging
process. The charging process will be terminated and the
charging plug of charging stations with charging socket type
2 will be unlocked.
The stop function with the multi-function button must
be enabled in the service interface during the setting-
up process of the charging station. See Chapter 6.3
"Configuration of the charging station" on page 19.
31
7.3.2 Re-activating the residual current circuit
breaker and circuit breaker
The multi-function button can be used to re-activate the
residual current circuit breaker (RCCB) and circuit breaker
(CB) inside the charging station mechanically from the
outside without opening the enclosure.
1. Press the multi-function button until you feel resistance.
2. Now press the multi-function button firmly up to the
end position.
Residual current circuit breaker (RCCB) and circuit breaker
(CB) are re-activated and charging station is operational
again.
7.3.3 Testing the integrated residual current circuit
breaker (RCCB)
The multi-function button can be used to trigger the test-
function of the residual current circuit breaker (RCCB) inside
the charging station from the outside without opening the
enclosure.
1. Insert a flat screwdriver with a blade width of 8 to
10 mm in the slot of the multi-function button.
2. Turn the multi-function button by 90 ° anti-clockwise.
3. Press the multi-function button briefly (about 2
seconds).
The residual current circuit breaker (RCCB) is triggered and
the fault display on the LED info bar flashes red.
4. Re-activate the residual current circuit breaker (RCCB)
(see Chapter 7.3.2 "Re-activating the residual current
circuit breaker and circuit breaker" on page 31).