Operation

(continued)
Resetting Your Inverter/Charger to Restore AC Power
Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your elec-
trical system. To restore normal functioning:
Overload Reset: Switch operating mode switch to "OFF" or "DC OFF" and remove some of the connected electrical load (ie: turn off some
of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch
back to either "AUTO/REMOTE" or "CHARGE ONLY."

Configuration

Set Configuration DIP Switches
Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation
depending on your application. Refer to the appropriate section to review the instructions for your specific model.
B4
Group A DIP Switches
Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see
diagram) as follows:
Select Battery Type—REQUIRED
A1
(All models)
CAUTION: The Battery Type DIP Switch setting must
match the type of batteries you connect, or your batteries
may be degraded or damaged over an extended period of
time. See "Battery Selection," p. 9 for more information.
Battery Type
Gel Cell (Sealed) Battery
Wet Cell (Vented) Battery
* Most of your connected appliances and equipment will perform adequately when your Inverter/Charger's High AC Input Voltage Point (DIP Switch #2 of Group A) is set to 135V and its Low AC Voltage Input Point (DIP Switches
#3 and #4 of Group A) are set to 95V. However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that would have little effect on equipment operation, you may wish to adjust these set-
tings. By increasing the High AC Voltage Point and/or decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings.
B3
B2
B1
Group B Dip Switches
A4
A3
A2
A1
Switch Position
Up
Down (factory setting)
INPUT C/B 10A
Select High AC Input Voltage Point
A2
for Switching to Battery—OPTIONAL*
(OEM models only)
Voltage
145V
135V
Charger Inhibit
A2
(Most models )
Function
Charger Inhibited
Charger Enabled
6R
A4
A3
A2
A1
OUTPUT C/B 12A
Group A Dip Switches
A4
A3
Switch Position
Up
Down (factory setting)
A4
A3
Switch Position
Up
Down (factory setting)
A2
A1
A2
A1