CONTROL PADS ON THE DEHUMIDIFIER
➑ Display
Shows the set % humidity level from 35% to 85%
or auto start/stop time (0~24) while setting, then
shows the actual ( ± 5% accuracy) room % humid-
ity level in a range of 30% RH(Relative Humidity)
to 90%RH(Relative Humidity).
Error Codes and Protection Codes:
AS- Humidity sensor error-Unplug the unit and
plug it back in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit
and plug it back in. If error repeats, call for service.

Other features

Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the
proper position. When the setting humidity is reached,
the unit will be shut off automatically. For some mod-
els, the fan motor will continue operating.
Auto Defrost
When frost builds upon the evaporator coils, the com-
pressor will cycle off and the fan will continue to run
until the frost disappears.
NOTE: When Auto defrosting operation, the unit may
make a voice of refrigerant flowing.it is normal.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart oper-
ation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
Smart dehumidifying mode
At smart dehumidifying mode, the unit will automat-
ically control room humidity in a comfortable range
45%~55% according to the room temperature. The
humidity setting function will be invalid.
PI- Unit is defrosting- Allow the unit time to automat-
ically defrost. The protection will clear after the unit
self defrosts.
P2- Bucket is full or bucket is not in right position-
Empty the bucket and replace it in the right position.
E3- Unit malfunction- Unplug the unit and plug it back
in. If error repeats, call for service.
EC- Refrigerant leakage detection- With this new
technology, the display area will appear " EC" when
the unit detects refrigerant leakage .call for service.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automati-
cally when the power resumes.
Setting the Timer
When the unit is on, first press the Timer button, the
Timer Off indicator light illuminates. It indicates the
Auto Stop program is initiated. Press it again the Time
On indecator light illuminates.lt indicates the Auto Start
is initiated.
When the unit is off, first press the Timer button, the
TIMER ON indicator light illuminates. It indicates the
Auto Start program is initiated. Press it again the Time
Off indecator lightilluminates.lt indicates the Auto Stop
is initiated.
Press or hold the UP or DOWN pad to change the
Auto time by 0.5 hour increments, up to 10 hours, then
at 1 hour increments up to 24 hours. The control will
count down the time remaining until start.
The selected time will register in 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
When the Auto start & Auto stop times are set, within
the same program sequence, TIMER ON OFF indica-
tor lights illuminate identifying both ON and OFF times
are now programmed.
Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto Start/Stop
function.
When LED display window displays the code of P2,
the Auto Start/Stop function will also be cancelled.