Kongskilde SupraVac 2000 Manual page 27

Tractor powered suction blower
Hide thumbs Also See for SupraVac 2000:
Table of Contents

Advertisement

Available languages

Available languages

Adjustment by short conveying
distances
2 - 4 meter
conveying
distances
If the suction blower is used with a short suction pipe
(2-4 meter) and standard loading equipment on the
pressure side, the correct balance between grain and
air is obtained, when the line between the red and
green area is pointing against the inner lower corner
on the air regulator. Part of the red area will then also
be visible on the air regulator.
Green
Red
Adjustment by conveying distances
up till 25 meter
Conveying
distances up
till 25 meter
When the conveying distance is increased, more air
must be available in the pipe system to ensure a stable
conveying.
The optimum adjustment is therefore, when less and
less of the red area gets visible, as the conveying
distance is increased. The limit between the green
and the red area on the air regulator is therefore an
inclined line.
Green
Red
27