Procedure #7: Lubrication
Install all transport locks before transporting or working underneath.
Coulter depth gauge wheel pivot: 40-hour interval.
Pivot grease
zerk
Figure 7.2
Turbo coulter hub: Use good quality wheel bearing or lithium grease for lubrication, but we suggest that you
grease the hub sparingly. Over-lubricating the hub will result in pre-mature seal failure, and an excessive
amount of grease in the hub cap/commutator. On an interval of 150 hours, 1-2 strokes of grease should
be sufficient.
grease zerk
Figure 7.2