Important note
Advantix bathroom drain
Careful planning is required for professional sealing. In addition,
depending on the individual dampness wear class and the type of foun-
dation, a suitable BS system with a building regulations certificate of
suitability must be chosen.
Furthermore, the following factors should be taken into account:
Drain or shower channel must be equipped with a special flange,
n
which has an adhesive surface and a width of at least 30 mm
To enable the material change from drain to screed, either a suitable
n
sealing cuff or sealing strip, which is designed for overlapping with
the BS with a width of at least 50 mm must be used.
The screed must be laid at a minimum incline of 1–2 %.
n
The installation must be carried out properly in acc. with the installa-
n
tion manual and the manufacturer's information.
1
2
9
Fig. 5: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 - grate
2 - top piece with adhesive flange
3 - tile
4 - tile adhesive
5 - bonded sealing
6 - screed
7 - sealing cuff
8 - mat
9 - adhesive flange
3
8
7
Product information
4
5
6
12 from 25