Replace hydraulic system fluid
Remove the plug in the inspection opening on the
hydraulic reservoir and use an oil extractor to suck out the
fluid through the inspection opening.
Replace the hydraulic system filter. Fill the new filter with
oil and lubricate the seal with a few drops of oil prior to
refitting it.
Refill the reservoir with new oil. Ensure that machine is
level prior refilling.
NOTICE! Do not overfill!
Replace engine fuel filter (spin-on-type)
NOTICE! Maintenance of the fuel filter should be done after
the valve of the pre-filter is closed.
Make sure the valve is open before you start the engine
(see engine manual)
Remove the fuel filter by turning it counterclockwise.
Replace the fuel filter. Beware of diesel that may spill. Fill
the new filter with diesel and lubricate the seal with a few
drops of diesel prior to refitting it.
MAINTENANCE AND SERVICE
Flush and clean radiator and cooling system
CAUTION! Let the engine cool down before
!
opening the radiator coolant lid.
Remove the back cover, put an extension on the valve and
open the valve. Remove the lid on top and empty the
system.
Close the valve and refill the radiator coolant.
For more information, see the "Technical data" section.
Fill up until the coolant level is between the two marks on the
radiator coolant overflow bottle when engine is cool.
The coolant level should reach the start of the tube inside.