Daily Maintenance
WARNING! Switch off the engine before
!
carrying out any checks or maintenance.
Check radiator coolant level.
WARNING! Let the engine cool down before
!
opening the radiator coolant lid.
Remove the lid and look down, the level should reach the
start of the tube inside. Fill with coolant if needed.
Check the engine's oil level
Check engine oil level without blade and the saw horizontal
for a flat saw level.
On the left side of the saw, check the engine oil level.
Make sure the level is between the limits.
Check blade guard for damage
Check the blade guard for cracks.
Never use a broken or damaged blade guard.
MAINTENANCE AND SERVICE
Check all hoses and clamps for damage or
looseness.
The image only shows some of the hoses and clamps.
Look for leakage on fuel, hydraulics and cooling system.
Tighten or replace as necessary.
Check air cleaner restriction indicator.
Check and clean the outer air filter if the air cleaner
indicator is red, remove the rear cover by opening the 3 air
filter housing clamps and pulling the housing off.
Clean the filter by blowing the element from inside out.
Use the lowest possible air pressure to remove the dust
without damaging the element.
Use 42-47 PSI (0,29-0,49 MPa;3,0-5,0 kgf/cm
compressed air to remove particulates.
Replace any damaged filters or gaskets and check air
hose and clamps for damages or looseness. Tighten or
replace as required.
NOTICE! No need to clean the inner filter on a daily basis.
The 3 air filter housing clamps can not be closed unless the
outer air filter is properly installed.