ELECTRICAL CONNECTION
WARNING: Do not connect the appliance to the electrical supply until after the gas
connection has been made.
120 VAC-60 Hz-Single Phase
120 VAC-60 Hz-Single Phase
120 VAC-60 Hz-Single Phase
Units with this electrical rating are factory supplied with a three-wire cord and three-
prong plug which fits any standard NEMA 5-15R 125 VAC, three-prong grounded
receptacle. A separate 15 amp supply is needed for each unit.
PLUMBING CONNECTIONS
WARNING: Plumbing connections must comply with applicable sanitary, safety and
plumbing codes.
Two water lines are provided, one for each compartment. Connect water supply line to
the 3/8" copper tube in at the rear of the steamer. The 3/8" copper tube supplies water
to both the generator tank and to condense live steam entering the drain line.
DRAIN CONNECTIONS (FIGURE 2)
The drain connection must be 1" IPS
vertically down, preferably with one elbow
only, and maximum length of 6 feet, piped
to an open air gap type drain.
CAUTION: In order to
avoid any back pressure
in the steamer, do not
connect solidly to any
drain connection.
9