Chapter 4 - Assembly / Operation / Maintenance; Wall Assembly; Installation Of The Wall-Mounted Ion Exchange Cartridge; Assembly Of The Floor-Standing Ion Exchange Cartridges - ELECTOR REFILL plus Series Operating Manual

Water filter system for deionization
Table of Contents

Advertisement

Available languages

Available languages

REFILL plus

Chapter 4 - Assembly / Operation / Maintenance

4.1 Wall assembly

3 x Ø 10,1
30
30

4.2 Installation of the wall-mounted ion exchange cartridge

Hold the cartridge horizontally in front of the wall bracket and place it with the connection nipples in
the bracket. Then rotate the cartridge to a vertical position.

4.3 Assembly of the floor-standing ion exchange cartridges

4.4 General operation

After installation, fill the water filter system with water and rinse it twice with the volume of the
cartridge before use. The ion exchange resin must not dry out. Always leave the water filter system
filled with water. Make sure that you always shut off the ball valves in the inlet and outlet after using
the water filter system. Never use a compact filling valve for automatic top-up without leakage
monitoring. You should only use the water filter system with open ball valves for automatic refilling of
the heating system if the system has a top-up system with leakage monitoring.
www.elector-water-treatment.com
Select an easily accessible location for wall mounting of the stainless
steel connection fitting. The masonry to which the water filter system
is to be installed must have sufficient strength and load capacity of
at least 20 kg. We do not recommend mounting the station on walls
with old sanding plasters.
The wall bracket has three holes for wall mounting according to the
adjacent drawing. Please use these for attaching it to the wall by
using the enclosed screws.
The ion exchanger cartridge is placed on the floor in front of the
connection fitting that has been mounted on the wall.
Connect the cartridge inlet (IN) via the flexible hose to the water
meter. Please connect the cartridge outlet (OUT) with the connector
of the connection fitting in which the MINIgarde capacity indicator is
installed.
Please note note 3.6!
The connecting pipes are delivered
bent, but may have been bent to an
unsuitable shape during transport.
You may have to carefully adjust the
bending radius by hand.
Page 28