5.2.5
Entries in the engine logbook
The monitoring of the engine system enables conclusions to be drawn on the behaviour of
the turbocharger.
The following operating data and measured values must be entered regularly in the engine
logbook of the enginebuilder:
¡
Rating and speed of the engine
¡
Air intake temperature
¡
Pressure of the charge air
¡
Pressure loss in the charge-air cooler
¡
Lubricating oil pressure and lubricating oil temperature
If present:
¡
Speed of the turbocharger
¡
Air temperature after the compressor and after the charge-air cooler
¡
Exhaust gas temperature before and after the turbine
¡
Pressure loss in the filter silencer.