4.3.5
Replacing the speed sensor
WARNING
Hot speed sensor
Danger of burns. The speed sensor can reach temperatures of more than
100 °C during operation.
Wear safety gloves when disassembling the speed sensor.
u
Wear safety gloves to protect against thermal hazards.
The speed sensor supplied by ABB is equipped with a sealing lip and an O-ring. No additional
gasket is required during assembly.
Fig. 20: Replacing the speed sensor
Part number
86505
Table 8: Tightening torque (86505)
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
u
lubrication
(Stopping the engine
Switch off the lubricating oil supply to the turbocharger.
u
Disconnect cable connector (86515) from speed sensor (86505).
u
Unscrew and remove defective speed sensor (86505).
u
Screw in new speed sensor (86505) as far as it will go and tighten.
u
Connect cable connector (86515) to speed sensor (86505).
u
Switch on lubricating oil supply to the turbocharger.
u
© Copyright 2020 ABB. All rights reserved.