Turbocharger
Hide thumbs Also See for A150-M67:

Advertisement

Operation Manual / 4 Product description / A150-M56/66/57/67 -
A155-M..
2 Removing and Installing / 2.2 Removing the turbocharger
2.2.2
Positioning the turbocharger for storage
WARNING
Risk of tipping
If the turbocharger is not positioned stably, it may tip over. This can result in
serious personal injury.
Place the turbocharger on a clean, level support.
u
Secure the turbocharger to prevent it from tipping over by using wooden
u
beams and wedges and by taking the centre of gravity into account.
Fig. 9: Turbocharger centre of gravity
01
Centre of gravity
Remove the turbocharger from the engine support.
u
Remove and dispose of the O-rings (42195, 42200).
u
Set down and secure the turbocharger properly at a suitable location.
u
Close or cover the openings of the turbocharger and support.
u
© Copyright 2020 ABB. All rights reserved.
HZTL4032_EN
Rev.P
March 2020

Advertisement

loading

This manual is also suitable for:

A155-m seriesA155-m56A155-m66A150-m56A150-m57