Nozzle ring compression PD
For the nozzle ring (56001) to be fixed during operation, it must be clamped between the
heat shield (42400) and the turbine casing (51000).
Fig. 59: Nozzle ring compression PD
42001
Bearing casing
42400
Heat shield
Product
A150-M
A155-M
Table 44: Nozzle ring compression PD
1. Measure values A, B, and S on cleaned surfaces.
2. Calculate compression (PD).
If the calculated value (PD) lies outside the specified range, contact an ABB Turbochar-
u
ging Service Station.
© Copyright 2020 ABB. All rights reserved.
51000
Turbine casing
56001
Nozzle ring
Nozzle ring compression PD [mm]
HZTL4032_EN
-0.17 ... 0.17