Removing the gas outlet casing
Variant with support
Fig. 43: Removing gas outlet casing with support 1
1. If present: Remove waste gate pipe.
2. Remove gas outlet casing insulation.
3. Remove insulation ring.
4. Remove fixing screws of support (61301) to bracket.
5. Fit swivel lifting eyes (S) to the gas outlet casing (61001). Attach lifting gear to swivel lift-
ing eye and secure to a crane hook.