SECTION 1 – INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBER, NETT WEIGHTS and DIMENSIONS
MODEL
WIDTH
mm
E350/34
350
E350/35
700
1.2 SITING
The appliance should be installed on a table, counter, or similar surface. Alternatively it can be mounted on the
purpose designed floor stand supplied by Falcon.
Should it require to be positioned in close proximity to a wall, partition, etc., a minimum clearance of 25mm at the
rear and sides is recommended.
A vertical clearance between plate and any overlying combustible surface of 900mm should be allowed. Fire
Regulations must be complied with.
1.3 ELECTRICAL SUPPLY
These units are designed for use on AC supplies only. The E350/34 griddle plate is for use on single phase supplies
only. The E350/35 model can be used on single-phase or alternatively on a 2-phase supply.
1.3.1 Supply Connection
The cable entry is located at the rear of the appliance and is suitable for 20mm conduit. A suitable isolating switch
must be provided with a minimum contact separation of 3 mm in all poles. All wiring must be executed in accordance
with the regulations listed on the cover of the manual.
THESE APPLIANCES MUST BE EARTHED.
A suitable terminal is provided for this purpose and must be used for this purpose.
Note
When connecting the E350/35, the line terminals must be connected using the link(s). See the diagram below.