Considerations Before Installing; Maintenance Safety - Extreme Networks Summit X460-G2 Series Installation Note

Hide thumbs Also See for Summit X460-G2 Series:
Table of Contents

Advertisement

Only trained service personnel should perform service to Extreme Networks switches and components.
Trained service personnel have read all related installation manuals, have the technical training and
experience necessary to be aware of the hazards to which they are exposed in performing a task, and
are aware of measures to minimize the danger to themselves or other persons.
WARNING!
This is a Class A product. In a residential environment this product may cause radio interference, in which
case the user may be required to take adequate measures.

Considerations Before Installing

The system is designed to operate in a typical Telco environment that is environmentally controlled.
Choose an indoor area that has the following characteristics:
-
Temperature-controlled and humidity-controlled, to ensure that the maximum ambient room
temperature shall not exceed the temperature specified in the product data sheet
-
Clean and free from airborne materials that can conduct electricity
-
Well ventilated and away from sources of heat, including direct sunlight
-
Away from sources of vibration or physical shock
-
Isolated from strong electromagnetic fields produced by electrical devices
-
Secured, enclosed, and restricted-access, ensuring that only trained and qualified service
personnel have access to the equipment
Establish at least 3 inches clearance on all sides for effective ventilation. Do not obstruct air intake
vents or ventilation grills on the front, side, or rear panel. Locate the system away from heat sources.
Make sure that your equipment is placed in an area that accommodates the product specifications
for power consumption and component heat dissipation.
Make sure that your power supplies meet the site power or AC power requirements of all network
equipment.

Maintenance Safety

Use only original accessories or components that are approved for use with this system.
Failure to follow these instructions may damage the equipment or violate required safety and
EMC regulations.
The chassis cover should be removed only by Extreme Networks personnel. This system contains no
customer-serviceable components. Repairs to the system must be performed by an Extreme
Networks factory service technician.
Disconnect all power cords before working near power supplies, unless a maintenance procedure
instructs you to do otherwise.
Replace a power cord immediately if it shows any signs of damage.
When you work with optical devices or other modular accessories, wear an ESD-preventive wrist
strap to reduce the risk of electronic damage to the equipment. Connect the other end of the strap to
an appropriate grounding point on the equipment rack. Leave the ESD-preventive wrist strap
Summit X460-G2 Series Switches Installation Note