Configuring The Network Settings - Comtrol Device Master UP Hardware User's Manual

16-port
Table of Contents

Advertisement

Configuring the DeviceMaster UP

Configuring the Network Settings

Default Network Settings
IP address:
192.168.250.250
Subnet mask:
255.255.0.0
Gateway address:
192.168.250.1
16 - Configuring the DeviceMaster UP
Use the following procedure to change the default network settings on the
DeviceMaster UP for your network.
Note: Technical Support advises configuring one new DeviceMaster UP at a time
to avoid device driver configuration problems. If you want to configure
multiple DeviceMaster UPs using the Assign IP to Multiple Devices option, see
Configuring Multiple DeviceMaster UPs Network Addresses
The following procedure shows how to configure a single DeviceMaster UP
connected to the same network segment as the Windows system. If the
DeviceMaster UP is not on the same physical segment, you can add it manually
using
Adding a New Device in PortVision DX
1. If you have not done so, install PortVision DX
Page 12).
2. Start PortVision DX using the PortVision DX desktop shortcut or from the Start
button, click Programs > Comtrol > PortVision DX > PortVision DX.
3. Depending on your operating system, you may need to click Yes to the Do you
want to allow the following program to make changes to this computer? query.
4. Click Scan to locate the Comtrol Ethernet-attached products including the
DeviceMaster UP on the network.
Note: If you do not have any RocketLinx managed switches or IO-Link
Masters, it saves scanning time if you do not scan for them.
on Page 31.
(Installing PortVision DX
DeviceMaster UP 16-Port Hardware User Guide: 2000596 Rev. B
on Page 31.