Setting Of Operating Parameters - Nakanishi E4000 CONTROLLER Operation Manual

Table of Contents

Advertisement

18 . SETTING OF OPERATING PARAMETERS

18 - 1 Entering Parameter Setting Mode
CAUTION
When in the parameter mode, normal operation of starting, stopping, etc. operation is not
possible.
When changing from the parameter mode to normal operation, be sure to toggle the Main Power
Switch OFF and ON again.
(1) Make sure that the Main Power Switch is turned OFF.
(2) While push and holding the Error Reset Button while turning the Power Switch ON at the rear of the
CONTROLLER.
(3) Hold the Reset Button down for 3 seconds while the CONTROL is powering up.
(4) The buzzer will ' BEEP ' 3 times, then release the Reset Button and Parameter Setting Mode will start.
Displayed.
18 - 2 Parameter Descriptions
Parameter types, contents, and default are detail in Table 8.
When checking a parameter or changing a parameter setting, refer to P90 " 18 - 4 Setting procedures " section.
Table. 8
Code
Types
Setting of Error Output
Mode
Setting AUTO Mode for
Motor Speed Control
Setting Fixed Motor
Speed
Setting Maximum Motor
Speed
Selection of External
Speed Control Mode
Selection of External
Motor Start Signal
Control Mode
Setting of Motor
Acceleration and
Deceleration Time
Temporary Motor /
Spindle Operation if
FAN has Stopped (80
Square Type)
Con rmation of
Parameter Setting
86
Changes the Error Output Signal, when an error occurs, from
normally open to normally closed.
When the control is in AUTO mode, the speed control is
adjustable from the CONTROLLER Panel, set the parameter
to
to adjust the speed in AUTO Mode.
When a Fixed Motor Speed is desired, set the parameter to
and set the desired locked in speed.
When a Maximum Motor Speed is desired, set the parameter
to
and set the maximum speed.
The following Rotation Speed options can be selected when
control mode is AUTO.
: Analog Signal
: Speed Point Signal
When control mode is in AUTO, please set the parameter
to
and set the desired rotating direction of the motor.
Activate Pin No. 2 to set a reverse direction along with the
start command.
If acceleration time of the Motor startup to Motor Maximum
Rotation Speed or deceleration time of from Maximum
Rotation Speed to motor stop need to be lengthened. Set
the parameter to
and set the desired acceleration /
deceleration time.
(Acceleration time and deceleration time are common.)
If the FAN has malfunctioned and stopped, the Motor /
Spindle can be temporarily operated.
Contents of the parameters that are set can be con rmed.
(
-
.) No parameter setting is necessary.)
Contents
: Pulse Signal
is
Default