Expert Menu ‒ Factory defaults
If the selection "Factory settings" in the "Expert menu" is confirmed, the device is reset to the
factory settings.
After confirming, the Initial Setup is started automatically.
Data of the factory dafaults: see chapter 7.2 "Factory defaults" on page 18.
Initial setup: see chapter 7.1 "Initial setup" on page 17.
Product manual 2CKA001473B9664 │ 01.03.2020
Connected load
– To provide the connected load in Watts: Adjustable in steps of
100 Watt.
No:
– The internal temperature value is not displayed.
Yes:
– The internal temperature value is displayed.
Due to environmental influences, the actual set value cannot always
be achieved.
In order to adjust the controller in the best way possible, the
temperature offset can be adjusted accordingly.
– Adjustable in steps of 0.1 °C.
The Offset also affects the displayed internal temperature value.
YES / NO
– If valve protection is activated with Yes, the load will be switched
ON every day at 10:00 for at least 5 minutes.
– This is important if standard mode is set to OFF.