Fast Flush Switch Replacement - Graco Mark V Premium Repair Manual

Electric airless sprayers
Table of Contents

Advertisement

Fast Flush Switch Replacement

Removal
1. Perform Pressure Relief Procedure; page 9. Wait
5 minutes before servicing.
2. Remove four screws and remove display cover.
3. Remove two screws and remove control panel.
4. Unplug Fast Flush switch from control board.
5. Unscrew Fast Flush switch from control panel.
3A2333B
ti13568a
ti13571a
ti13572a
ti13573a
Installation
1. Apply thread sealant to end of Fast Flush switch.
Hand tighten Fast Flush switch until it is tight
against control panel.
ti13574a
2. Add thread sealant and tighten jam nut against
threaded bus.
ti13576a
3. Connect Fast Flush switch to control board.
4. Replace control panel and tighten two screws.
5. Replace display cover and tighten four screws.
Fast Flush Switch Replacement
ti13572a
ti13571a
ti13568a
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mark v max

Table of Contents