Graco Mark V Premium Repair Manual page 16

Electric airless sprayers
Table of Contents

Advertisement

Troubleshooting
TYPE OF PROBLEM
Sprayer does not run at all
Digital display shows E=06
Control board status light blinks
6 times repeatedly
Sprayer does not run at all
Digital display shows E=09
Control board status light blinks
9 times repeatedly
Sprayer does not run at all
Digital display shows E=10
Control board status light blinks
10 times repeatedly
16
WHAT TO CHECK
Allow sprayer to cool. If sprayer
runs when cool, correct cause of
overheating. Keep sprayer in cooler
location with good ventilation. Make
sure motor air intake is not blocked.
If sprayer still does not run, follow
Step 1.
Check the connections. Control
is not receiving a motor position
sensor signal
Check to see if control board is over
heating.
HOW TO CHECK
NOTE: Motor must be cooled down for the test.
1.
Check thermal device connector (yellow wires)
at control board.
2.
Disconnect thermal device connector from control
board socket. Make sure contacts are clean and
secure.
Measure resistance of the thermal device. If reading
is not correct, replace motor.
Check Motor Thermal Switch: Unplug thermal
wires. Set meter to ohms. Meter should read the
proper resistance for each unit (see table below).
-
MARK V
ti13140a
3.
Reconnect thermal device connector to control
board socket. Connect power, turn sprayer ON and
control knob 1/2 turn clockwise. If sprayer does not
run, replace control board.
1.
Turn power OFF.
2.
Disconnect motor position sensor and inspect for
damage at connectors.
3.
Reconnect sensor.
4.
Turn power ON. If error continues, replace motor.
1.
Make sure motor air intake is not blocked.
2.
Make sure fan has not failed.
3.
Make sure control board is properly connected
to back plate and that conductive thermal paste
is used on power components.
4.
Replace control board.
5.
Replace motor.
Resistance Table:
3.9k ohms
3A2333B